Specifications
Load Cell Excitation: |
10VDC (8-350 ohms load cells) |
Load Cell Wiring: |
4 or 6 Wire |
Analog Signal Input Range: |
0.3mV/V - 3.3mV/V |
Conversion Rate: |
10 updates/second (max.) |
Display Graduations: |
10,000 NTEP, 80,000 Industrial |
Linearization: |
5 points |
Decimal Point Selection: |
0 - 0.0 - 0.00 - 0.000 - 0.0000 |
Display Increments: |
1, 2, 5, 10, 20, 50, 100 |
Automatic Zero Tracking (AZM): |
± 0.5, ±1.0 or ± 3.0 grads. |
PAZ and AZM Aperture: |
1.9% or 100% of Full Scale |
Motion Band: |
± 1.0 or ± 3.0- graduations, (1) second
delay |
Set Point Output Control: |
(4) bipolar 5VDC logic levels |
Serial: |
Port 1 - (Full Duplex) RS232, 20mA, opt
RS485
Port 2 - (Simplex) RS232, 20mA |
Units: |
lb/kg |
Input Power: |
120/240VAC, 50/60HZ, Battery or External
DC |
Approvals: |
NTEP, CSA, CE |
Operating Temperature: |
-10°C to +40°C |
Enclosure: |
NEMA 4X |
|